The mechanical behaviour of adhesively bonded composite joints under repeated axial impacts at different temperatures
Tarih
2017Yazar
Kemiklioglu, U. and Sayman, O. and Soykok, I.F. and Akderya, T. and Dere, R.
Üst veri
Tüm öğe kaydını gösterÖzet
In this study, the failure strength of single-lap adhesively bonded joints was investigated. The glass fibre epoxy composites used as adherends were manufactured by using a vacuum-assisted resin infusion method. These composites were bonded with a commercial material of epoxy-adhesive DP-460, which can be cured easily at room temperature. The specimens were built by bonding, and then repeated axial impact loads having various energy levels (0, 5, 10, 15, and 20 J) were implemented to the single-lap adhesively bonded composite joints at different temperatures (-20°C, 0°C, 20°C, 40°C, and 60°C). Subsequently, the specimens were exposed to static tensile loading at the same temperatures as those applied during the primary impacts. The variation in failure loads due to the effects of repeated axial impact loadings at different temperatures were investigated. Generally, the increase of impact energy level from 0 to 20 J leads to a gradual decrease in failure loads at all temperature levels except for the specific value of 40°C. © 2017 Walter de Gruyter GmbH, Berlin/Boston.
Bağlantı
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85037522489&doi=10.1515%2fsecm-2015-0509&partnerID=40&md5=bf83d5a6663edf9d914f683d7694ff26http://hdl.handle.net/20.500.12481/11779
Koleksiyonlar
- Scopus [2994]