Show simple item record

dc.contributor.authorYeşim BAYTUR;Yıldız UYAR;H. Tayfun ÖZÇAKIR;Ümit İNCEBOZ;Selman LAÇİN;GÜRCAN ERBAY;Hüsnü ÇAĞLAR
dc.date.accessioned2020-06-30T10:26:32Z
dc.date.available2020-06-30T10:26:32Z
dc.date.issued2004
dc.identifier.citation2
dc.identifier.urihttps://app.trdizin.gov.tr/publication/paper/detail/TkRVNU16RXg=
dc.identifier.urihttp://hdl.handle.net/20.500.12481/2125
dc.description.abstractAmaç: Termdeki fetuslarda, başarılı doğum indüksiyonuna cevabı belirlemede transvajinal serviks ölçümü, Bishop skoru ve pariteyi karşılaştırmak. Yöntem: Bu prospektif çalışmada, 37-42 hafta arasında doğum indüksiyonu uygulanan 97 gebe kadın çalışmaya alındı. Bishop skoru dijital muayeneyle, serviks ölçümü ise transvajinal ultrason ile yapıldı. indüksiyon ajanı olarak misoprostol ya da oksitosin kullanıldı. Serviks uzunluğu, Bishop skoru, parite, dilatasyon, efasman, yaş ve kullanılan indüksiyon ajanının, indüksiyon -doğum süresine ve sezaryen riskine etkisi araştırıldı. istatistiksel yöntem olarak Pearson korelasyon, çoklu doğrusal ve lojistik regresyon modeli ve ROC eğrisi kullanıldı. Ayrıca sürekli değişkenleri karşılaştırmak için Mann Whitney U test, kategorik değişkenler içinse ki-kare testi kullanıldı. Bulgular: Hastaların %18,6’sı sezaryen ile doğum yaptı. indüksiyon - doğum süresi ile serviks uzunluğu, dilatasyon, efasman ve Bishop skoru korelasyon gösterirken (sırasıyla r: 0,448 P<0,0001, r:-0,382 P<0,0001, r:- 0,357 P:0,02, r:-0,261 P:0,01) parite, yaş ve indüksiyon ajanı ile korelasyon bulunamadı. Çoklu doğrusal regresyon modelinde indüksiyon - doğum süresini belirlemede, tek bağımsız deşişken serviks uzunluğuydu (t:4,247, %95 GA: 0,146-0,404 P< 0,0001). Sezaryen olasılığı için lojistik regresyon modelinde ise serviks uzunluğu yine tek bağımsız gösterge idi ( OR:1,114 %95 GA: 1,024-1,211 P <0,05). ROC e¤risi, sezaryen riskini belirlemede, serviks uzunluğu için en iyi eşik değerin 18 mm olduğunu ve serviks uzunluğunun Bishop skorundan daha iyi olduğunu gösterdi (eğri altındaki alan: 0,709’a karşı 0,390). Serviks uzunluğu <18 mm olan hastalarda sezaryen oranı, > 18 mm olanlardan daha azdı (%0’a karşı %22. Duyarlılık ve seçicilik sırasıyla %100 ve %23). Sonuç: Doğum indüksiyonu uygulanan hastalarda, indüksiyon- doğum süresini ve sezaryen olasılığını belirlemek açısından yalnız transvajinal serviks uzunluğu kullanılabilir. Bishop skoru ve parite ise birer bağımsız değişken olarak anlamlı görünmemektedir.
dc.description.abstractObjective: In term fetuses, to compare the measurement of the cervix by transvaginal ultrasound with Bishop score and parity to predict successful labor induction. Methods: In this prospective study, ninety-seven pregnant women undergoing labor induction between 37-42 weeks of gestation were enrolled in this study. The Bishop score was assessed by digital examination whereas the cervical length was measured by transvaginal sonography. It was investigated the impact of cervical length, Bishop score, parity, dilatation, effacement, age and induction agent on induction to delivery interval and the risk of cesarean section. Pearson correlation, multiple linear and logistic regression model and ROC curve were used as statistical methods. Furthermore Mann Whitney U test for continuous and chi-square test for categoric variables were used. Results: Cesarean delivery occured in 18,6 % of the patient. There were a correlation between induction to delivery interval and cervical length, cervical dilatation, effacement and Bishop score (r: 0,448 P&lt;0,0001, r:-0,382 P&lt;0,0001, r:- 0,357 P:0,02, r:-0,261 P:0,01, respectively), whereas it was not found a correlation with parity, age and induction agent. In multiple linear regression model, the cervical length is the only independent factor predicting induction to delivery interval (t:4,247, 95 % CI: 0,146-0,404 P&lt; 0,0001). Alo, in logistic regression model for cesarean probability, the cervical length is the only independent factor (OR:1,114 95%CI: 1,024-1,211 P &lt;0,05). Receiver-operating characteristics (ROC) curves for predicting cesarean delivery demonstrated that the best cut off value was 18 mm for cervical length and cervical length was better for predicting of cesarean delivery than Bishop score (area under curve = 0,709 versus 0,390). The patients with cervical length &lt;18 mm were associated with lower cesarean rate comparing patients with cervical length &gt;18 mm (%0 versus %22, sensitivity and specificity %100 and % 23 respectively). Conclusion: In patients undergoing induction of labor, only the cervical length provide significant independent prediction of the likelihood of caserean section and induction to delivery interval. It doesn&amp;#8217;t seem parity and Bishop score add significant independent information.
dc.language.isotur
dc.titleDoğum indüksiyonu öncesinde transvajinal serviks ölçümü: Bishop skoru ve paritenin değerlendirilmesi
dc.title.alternativeTransvaginal ultrasound assessment of the cervix, bishop score and parity before labor induction
dc.typeRESEARCH
dc.contributor.departmentCELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ;CELÂL BAYAR ÜNİVERSİTESİ
dc.identifier.nameOfPublishedMaterialPerinatoloji Dergisi
dc.identifier.volume12
dc.identifier.issue1
dc.identifier.startpage33
dc.identifier.endpage37
dc.identifier.issn/e-issn1300-5251;1305-3132


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • TR - Dizin [3877]
    TR - Dizin İndeksli Yayınlar Koleksiyonu

Show simple item record